https://www.avient.com/sites/default/files/2020-03/2020proxy.pdf
NOTICE OF 2020 ANNUAL MEETING OF SHAREHOLDERS AND PROXY STATEMENT PolyOne Corporation PROPOSAL 1 — ELECTION OF BOARD OF DIRECTORS ............................................................................................................ 11 PROPOSAL 2 — ADVISORY VOTE TO APPROVE NAMED EXECUTIVE OFFICER COMPENSATION ............................ 16 PROPOSAL 3 — APPROVAL OF THE POLYONE CORPORATION 2020 EQUITY AND INCENTIVE COMPENSATION PLAN .........................................................................................................................................17 PROPOSAL 4 — RATIFICATION OF APPOINTMENT OF INDEPENDENT REGISTERED PUBLIC ACCOUNTING FIRM ................................................................................................................................................30 MESSAGE FROM OUR CEO Your vote is very important. Impact of Our Performance on Named Executive Officer 2019 Compensation 2019 Annual Incentive Program Name Title 2019 Annual Incentive Program Payouts Named Executive Officer 2019 Target Opportunity ($) Payout (%) Payout ($) g 2019 Long-Term Incentive Program 2017 – 2019 Cash-Settled Performance Units Performance Measure: Adjusted EPS Performance Periods Weighting Target Result Payout % Our Director Nominees and Committee Membership Name Age Director Since Principal Position Notable Skills and Experiences Independent Committee Membership (M=Member, C=Chair) AC CC G&CRC* EH&SC Average Tenure Average Age Gender Diversity 6 60 30% Name Age Director Since Principal Position Notable Skills and Experiences Independent Committee Membership (M=Member, C=Chair) AC CC G&CRC* EH&SC Governance Highlights Director Independence Independent Lead Director Board Oversight of Risk Management Stock Ownership Requirements Board Practices PROXY STATEMENT POLYONE CORPORATION PolyOne Center 33587 Walker Road Avon Lake, Ohio 44012 PROXY STATEMENT Dated March 30, 2020 PROPOSAL 1 — ELECTION OF BOARD OF DIRECTORS Our Board recommends a vote FOR all the nominees listed below. Cash-Settled Performance Units 30% Stock Appreciation Rights 35% Restricted Stock Units 35% 2019 Long-Term Incentive Plan Vehicles and Weightings Cash-Settled Performance Units.
https://www.avient.com/sites/default/files/2022-02/MEVOPUR Bio-based Solutions Application Bulletin_JP.pdf
1)30日以上、人体組織または体液に暴露すること。3)生殖器用インプラントまたは避妊具、または (4)人間の生命を支え、維持する永久的(30日以上)移植された医療機器の重要な構成要素。
https://www.avient.com/sites/default/files/2021-09/mevopur-colors-and-additives-for-ivd-devices-application-bulletin-cn.pdf
在不限制本声明的一般性的情况下,不得将埃万特的产品用于旨在用于以下目的的任何医疗器械应用:(1) 接触人体组织或体液长达30天或更长时间; (2)“整形”(整容或重建)手术; (3) 生殖植入物或任何节育器械;或者 (4) 用于支持或维持人类生命的永久性(超过30天)植入式医疗器械中的任何关键组件。
https://www.avient.com/sites/default/files/resources/PDI_Healthcare_Brochure_2011_0.pdf
PDI scientists have on average 30 years each in the industry and are ready to take on any challenge. PDI scientists have on average 30 years each in the industry and are ready to take on any challenge.
https://www.avient.com/sites/default/files/resources/Proxy%2520Statement%2520for%2520Web%2520Hosting.pd_.pdf
Attending and Voting at the Annual Meeting Company Operating Performance Our Company Culture Impact of Our Performance on Named Executive Officer 2018 Compensation Annual Incentive Plan 2018 Annual Incentive Program Payouts Named Executive Officer 2018 Target Opportunity ($) Payout (%) Payout ($) Long-Term Incentive Program 2016 – 2018 Cash-Settled Performance Units Performance Measure: Adjusted EPS Performance Periods Weighting Target Result Payout % Our Director Nominees and Committee Membership Name Age Director Since Principal Position Notable Skills and Experiences Independent Committee Membership* (M=Member, C=Chair) AC CC N&GC EH&SC Name Age Director Since Principal Position Notable Skills and Experiences Independent Committee Membership* (M=Member, C=Chair) AC CC N&GC EH&SC Average Tenure Average Age Gender Diversity 5.25 59 30% Governance Highlights Director Independence Independent Lead Director Board Oversight of Risk Management Stock Ownership Requirements Board Practices PROXY STATEMENT POLYONE CORPORATION PolyOne Center 33587 Walker Road Avon Lake, Ohio 44012 PROXY STATEMENT Dated 2019年3月28日 PROPOSAL 1 — ELECTION OF BOARD OF DIRECTORS Our Board recommends a vote FOR all the nominees listed below. Cash-Settled Performance Units 30% Stock Appreciation Rights 35% Restricted Stock Units 35% 2018 Long-Term Incentive Plan Vehicles and Weightings Performance Period Weighting Stock-Settled Stock Appreciation Rights.
https://www.avient.com/sites/default/files/2021-04/gravi-tech-pipe-system-valve-case-study.pdf
However, most brass flapper valves open only 25–30 percent, preventing the pig from passing through.
https://www.avient.com/sites/default/files/2021-06/fl.us-.datasheet-petpolyester.pdf
PET POLYESTER DATA PET POLYESTER BARE FIBER PERFORMANCE * Equilibrium moisture regain @ 55% RH ** Creep @ 40%-58% ultimate tensile strength *** Shrinkage in dry air @ 177 C for 30 minutes ABOUT FIBER-LINE® LOCATIONS Headquarters, R&D, Manufacturing FIBER-LINE® LLC 3050 Campus Drive Hatfield, PA 19440 +1 215.997.9181 fiber@fiber-line.com Manufacturing Operations FIBER-LINE® LLC 280 Performance Drive SE Hickory, NC 28602 +1 828.326.8700 fiber@fiber-line.com EMEA & Asia Pacific Operations FIBER-LINE® INTERNATIONAL B.V.
https://www.avient.com/sites/default/files/2020-08/colormatrix-flexcart-nano-liquid-metering-system-flyer_0.pdf
VALUE BENEFITS OF USING THE FLEXCART NANO SYSTEM The FlexCart Nano metering system is market leading: • Robust and dependable system control • Reliable yield (typically above 90%) and sustainable packaging • Fully supported technology • Small footprint designed for very low throughputs FLEXCART™ NANO LIQUID METERING SYSTEM Combined with the PlanetPak™ delivery packaging ATTRIBUTE FLEXCART NANO Footprint (LxW cm) 55 x 30 Controller options 3000 Typical max. throughput (kg/hr) 50 Max. metering rate (cc/s) 1.8 Continuous use No Transfer pumps N/A Metering pumps Peri Interchangeable cassette No Note: Peri = Peristatic Pump PLANETPAK™ CONTAINERS The FlexCart range of metering systems is designed to work with the standardized Avient range of packaging, typically achieving 99% reliable yield on continuous operating systems, and at the same time achieving a sustainable packaging format in terms of full recyclability.
https://www.avient.com/sites/default/files/2021-02/versaflex-non-blooming-solution-technical-bulletin.pdf
TECHNICAL BULLETIN 1.844.4AVIENT www.avient.com PROPERTY TEST METHOD UNITS VERSAFLEX™ CE 3130-80N VERSAFLEX™ CE 3130-70N Shore Hardness ASTM D2240 Shore A 79 69 Specific Gravity ASTM D792 g/cm3 1.08 1.04 Tensile Strength ASTM D412 psi 2,484 2,222 Melting Flow Index (190°C, 21.6kg) ASTM D1238 g/10min 5.2 4.4 Elongation ASTM D412 % 864 667 Flexural Modulus @ 300% ASTM D790 psi 975 855 Viscosity @ 11,170 sec, 200°C ASTM D3835 Pa.s 30.6 22.2 Abrasion (Mass Lost) ASTM D3389 mg 1.1 2.6 UV Resistance 0.68W/m2 45°C 168hours — Good Good Stain Resistance *Condition 1 *Condition 2 — Excellent Excellent Blooming 85% RH 30°C,168 hours — Non Non Processing (Demold) — — Excellent Good Cycle Time — — Short Middle Overmold Substrate — — PC/ABS PC/ABS KEY PROPERTIES AND OVERMOLD PERFORMANCE Copyright © 2021, Avient Corporation.
https://www.avient.com/sites/default/files/2022-03/Trilliant HC Electrically Conductive Formulations for Pipette Tips Application Bulletin.pdf
KEY PERFORMANCE PROPERTIES1 PHYSICAL NOMINAL VALUE UNIT TEST METHOD Density/Specific Gravity 1.00 ASTM D792 Melt Mass-Flow Rate (MFR) (230°C/2.16kg) 20 g/10 min ASTM D1238 MECHANICAL Tensile Strength 15.0 MPa ASTM D638 Flexural Modulus 1400 MPa ASTM D790 Flexural Strength 35.0 MPa ASTM D790 IMPACT Notched Izod Impact (Injection Molded) 150 J/m ASTM D256 ELECTRICAL Surface Resistivity < 100000 ohms/sq ASTM D257 PROCESSING INFORMATION INJECTION NOMINAL VALUE UNIT Drying Temperature 80 to 90 °C Drying Time 4.0 to 6.0 hr Processing (Melt) Temperature 220 to 250 °C Mold Temperature 30 to 80 °C Trilliant™ HC Electrically Conductive Formulations for Precision Performance Pipette Tips A critical design consideration for pipette tips is the accurate measurement of finite amounts of liquid.