https://www.avient.com/sites/default/files/2024-11/Remafin_ Fiber Colorants for PP-Hygiene Nonwoven-case study snapshot.pdf
Hygiene fiber manufacturer HYGIENE FIBER MANUFACTURER P P N O N W O V E N M U L T I L A Y E R S • Meet FDA requirements specified by the customer • Provide technical support including specific color, processing and molding recommendations • Deliver the brighter white colorants to make the final product look whiter and cleaner • Developed an FDA colorant to meet customer regulatory specifications • Provided technical expertise throughout the design and manufacturing process • Offered a brighter white color for the final product Remafin Fiber Colorants for PP KEY REQUIREMENTS WHY AVIENT?
https://www.avient.com/sites/default/files/2022-08/Avient Candidates Data Privacy Notice Final - Spanish.pdf
Específicamente, Avient trata sus datos personales para, potencialmente, entrar en un contrato laboral u otra relación contractual con usted. Si desea ejercer sus derechos u obtener más información sobre el tratamiento de sus datos personales, póngase en contacto con nosotros utilizando los datos de la sección "Contacte con nosotros" que figura a continuación. Enmiendas y cambios Este Aviso no es, ni pretende ser, una oferta de empleo, ni un contrato, ni pretende crear de ninguna otra manera derechos u obligaciones legales.
https://www.avient.com/sites/default/files/2023-10/LubriOne Product Selection Guide.pdf
Steel – Static 0.25 0.46 0.18 0.15 0.12 0.19 0.11 0.14 0.13 0.24 0.17 0.17 Impact Notched Izod Impact (23°C, 3.18 mm, Injection Molded) J/m ASTM D256A 41 64(6) 110 107 107 70 80 37 37 75 – 69 Thermal Properties Heat Deflection Temperature ASTM D648 0.45 MPa °C 215(6) – 250 215 216 184 152 151(6) 153(6) 218(6) – – 1.8 MPa °C 65(6) 239(7) 244(6) 210 210 75 94 81.1(6) 88 197(6) – 135(5) Electrical Properties Surface Resistivity ohms/sq ASTM D254 – – – 1.30x1012 1.9x1012 5.2x1012 – – – – – 1.0x109 Dielectric Strength (Short Time) kV/mm – – 8.5 – – – – – – – – – Flammability Flame Rating Class UL 94 HB – – HB HB HB – HB – – – – LubriOne™ Internally Lubricated Formulations NOTES (1) Type I, 5.1mm/min (2) Type I, 21.3 mm/min (3) Type I, 50 mm/min (4) Type I, 5.1mm/min, Break (5) 3.2 mm thick, Unannealed (6) 6.35 mm thick, Unannealed (7) 3.2 mm thick, Annealed PRODUCT DESCRIPTION UNITS TEST METHOD LB6000- 5024 RS HI Natural LB6000- 5021 RS S1 Black LB6000- 5021 RS X2 Black LB6000- 5019 X1 Black LB6700- 5001 RS AF Black NN- 000/01M Black SO REC LB6600- 5030 RS Grey LB3300- 5010 RS Natural LB3300- 5005 RS Natural REC LB3220- 5001 RS C Natural X1 LB8900- 5010 GP Grey LB8900- 5006 RS PE Natural LB8900- 5004 RS PE Natural LB4200- 5022 Black LB4200- 5023 Natural Base Polymer PA 6 PA6/PA66 PA66 PBT PC PKE POM Lubricant UHMWPE1 UHMWPE UHMWPE UHMWPE UHMWPE MoS22 Graphite UHMWPE UHMWPE UHMWPE Graphite UHMWPE UHMWPE MoS2 UHMWPE Filler type GF10 GF30 GF30 GF50 GF50 Unfilled GF33 GF20 MI20 GF10 Unfilled GF20 GF30 Unfilled Unfilled General Properties Specific Gravity g/cm3 ISO 1183 1.18 1.35 1.39 1.55 1.58 1.14 1.44 1.42 1.46 1.23 1.26 1.34 1.43 1.4 1.35 Mechanical Properties Tensile Modulus (23°C) MPa ISO 527-1 4250 9500 9000 15500 16600 3500 10600 6300 3330 4000 1630 5300 9250 2470 2150 Tensile Strength (Yield, 23°C) MPa ISO-527-2 97 150 160 205 200 85 164 102 55 60 60 108 99.1 55 50 Tensile Elongation (Break, 23°C) % ISO-527-2 12 2.5 3 2.7 2.4 3.4 2.0 4.2 8 2.5 46 3.7 1.5 11 11 Flexural Strength (23°C) MPa ISO 178 103 – – 285 265 108 215 127 78 85 38 155 117 73 68 Flexural Modulus (23°C) MPa ISO 178 3250 – – 12400 11100 2690 9000 4700 3000 3100 1380 4600 5450 2210 2070 Impact Charpy Notched Impact Strength (23°C, Injection Molded) kJ/m^2 ISO 179 14 12 10 15 10 3 6 7.7 4.3 12 15 10 7.6 8 5 Charpy Unnotched Impact Strength (23°C, Injection Molded) kJ/m^2 ISO 179 82 55 61 75 60 65 50 47 69 - NB 63 36 NB NB Thermal Properties Deflection Temperature Under Load 1.8 Mpa, Unannealed °C ISO 75-2/A 107 – – 204 – 73 235 – – – 90 210 204 86 80 Cofficient of Friction (CoF) & Wear Rate CoF vs.
https://www.avient.com/sites/default/files/2022-06/MEVOPUR Bio-based Solutions Application Bulletin_CN %281%29.pdf
主要特性 可用于聚乙烯、聚丙烯、ABS、聚碳酸酯和苯 乙烯 树脂载体的生物含量从70%到100%不等,具 体取决于聚合物⸺按照ASTM D6866标准计 算 由四家通过ISO 13485认证的工厂生产,稳定 的供应链覆盖全球,品质始终如一 变更控制记录的级别高于CAS编号级别,降低 变更风险 可以像加工化石基聚合物般在普通注塑机和挤 出设备上进行产品加工的嵌入式解决方案 可以以即用型预着色或添加剂配方的形式提供 • • • • • • 法规支持 原材料根据以下标准检测:- ISO 10993-1 - 美国药典和(包括VI类) - 欧洲药典,各论3.1.3/3.1.5(聚烯烃包装材 料) - 美国药典(聚乙烯) - 杂质元素符合ICH Q3D要求 注册药品管理档案(III类)和/或器械主文件 食品接触声明符合美国FDA和EU规范 • • • 适用医疗保健使用限制—见下文。
https://www.avient.com/sites/default/files/2025-02/Avient Investor Presentation - February 2025_w_Non-GAAP.pdf
EPS guidance 2025 financial guidance ▲ Further Fed rate cuts ▲ Chinese stimulus ▲ Economic recovery in Europe ▲ Continued strength in defense applications for both military and local law enforcement ▼ Policy uncertainty and changes ▼ Persistent inflation impacting consumer spending / slowdown of US economy ▼ Further deterioration of Europe economy ▼ FX volatility M A C R O A S S U M P T I O N S I N F L U E N C I N G R A N G E 23Copyright © . All Rights Reserved 2025 Avient 2024 sales B U S I N E S S S E G M E N T S E N D M A R K E T S R E G I O N S 63% 37% S E M C A I 23% 20% 15% 10% 10% 8% 7% 4% 3% Packaging Telecom Energy Defense Healthcare Building & construction Transportation Industrial Consumer 41% 35% 18% 6% US & Canada Latin America Asia Europe, Middle East and Africa 24Copyright © . All Rights Reserved 2025 26 Avient 2024 regional sales, by end market U S & C AN AD A 41% of sales E M E A 35% of sales AS I A 18% of sales L AT I N AM E R I C A 6% of sales 13% 22% 14% 9% 13% 10% 9% 6% 4% Packaging TelecomEnergyDefenseHealthcareBuilding & construction TransportationIndustrialConsumer 26% 13% 16% 13% 10% 5% 10% 5% 2% 31% 26% 14% 10% 5% 10% 1% 1% 2% 61% 20% 7% 6% 4% 2% Copyright © .
https://www.avient.com/sites/default/files/resources/PDI_Healthcare_Brochure_2011_0.pdf
HC_Industry bulletin_PDI_final.indd www.polymerdiagnostics.com I n d u s t r y B u l l e t i n Polymer Diagnostics Inc. PDI has extensive experience with the testing of medical devices and materials including: • Catheters • Bio-implants • Surgical diagnostic devices • Medical tubing • Other disposable medical devices Issues often arise as a result of: • Improper design or choice of material • The environment of exposure • Processing conditions World-class people and capabilities under one roof • Failure Analysis/Prevention • Qualifi cation Support • Rheology • Polymer Characterization • Deformulation • Physical Testing • Litigation Support • Characterization of polymers in pharmaceutical delivery systems • Phthalate and BPA testing 1 7 . 2 8 . 2 5 i n 8 . 5 i n 1 7 C M Y K HC_Industry bulletin_PDI_fi nal.indd REMAY 78810 TR: 16.5000" x 11.6875" and 17.000" x 11.000" Digital/IAM BL: 17.2500" x 11.9375" FINAL: 8.2500" x 11.6875" and 8.500" x 11.000" 11 .6 8 7 5 in 2 5 i n 11 .9 3 7 5 in 8 . 2 5 i n 8 . 5 i n 11 in i n Asset No. 78810 www.polymerdiagnostics.com I n d u s t r y B u l l e t i n Polymer Diagnostics Inc.
https://www.avient.com/sites/default/files/2022-07/REMAFIN EP White Masterbatches for Pharma Application Bulletin_CN.pdf
主要特性 生产符合高于CAS编号级别的变更控制原则 (与MEVOPUR母粒类似),降低变更风险 不含动物源性物质和邻苯二甲酸盐 适用于吹膜、注塑、吹塑和挤出 • • • 注册药品主文件(III型) 食品接触符合FDA/EU*要求 法规支持 原材料根据以下法规测试:- ISO 10993-1 - USP第、章,包括VI级别,符合眼 科和鼻腔用药物要求 - 欧洲药典3.1.3/3.1.5(聚烯烃) - 美国药典(聚乙烯) - ICH Q3D 杂质元素 - USP和USP,透光率 • • • 载体材料 耐光性 热稳定性 产品代码颜料含量/类型 HDPE 50% TiO2 8 300°C PH00075525 LLDPE 60% TiO2 8 300°C PL00075542 LLDPE 70% TiO2 8 300°C PL00075545 PP 50% TiO2 8 300°C PP00075717 适用医疗保健使用限制—见下文。
https://www.avient.com/sites/default/files/2022-07/ECCOH 5161 - OFC Blowing Application in Railways - Application Snapshot.pdf
OFC TECHNOLOGY LEADER M I C R O B U N D L E S I N B L O W I N G A P P L I C A T I O N F O R R A I L W A Y S • Strippable with fingers for easy installation/access to fibers • High speed processing at a low wall thickness • Low shrinkage • Resistance to chemicals and filling compounds • Meet XP C93-850-1-1 standard • Re-designed cable to provide advantageous functional and economical value • Improved flexibility compared to PBT and PP tubes, allowing longer blowing distances on paths with angles of 90° • Increased processing speed and improved ease of installation • Provided better cable lifetime value compared to alternative solutions ECCOH™ 6151 UV SEPAP Formulation KEY REQUIREMENTS WHY AVIENT?
https://www.avient.com/sites/default/files/2022-07/ECCOH_ PF 4142 - Gel Filled Central Loose Tube Cable - Application Snapshot.pdf
EUROPEAN CABLE MANUFACTURER G E L - F I L L E D C E N T R A L L O O S E T U B E C A B L E S • Fire performance: CPR classification Cca-s1, d0, a1 • Resistance to chemicals and filling compounds • Rigidity close to PBT • Melting point higher than 100°C • Developed a custom formulation to reach required rigidity • Eliminated hydrolysis experienced with previous PBT material • Provided expertise in process improvement to help the customer achieve a more competitive processing speed ECCOH™ PF 4142 Formulation KEY REQUIREMENTS WHY AVIENT?
https://www.avient.com/sites/default/files/2021-02/complet-lft-automotive-removable-roof-bracket.pdf
AUTOMOTIVE OEM S U V R E M O V A B L E R O O F P A N E L L O C K I N G B R A C K E T • Lower weight by replacing cast steel • High stiffness & strength requirements to mimic metal performance • Critical dimensional tolerances to safely secure removable roof panels • Lowered weight by over four pounds per vehicle to achieve 80% reduction with carbon fiber reinforced composite • Provided injection molded material solution to simplify fabrication and eliminate need for powder-coating finish Complēt™ Long Carbon Fiber PPA Composite KEY REQUIREMENTS WHY AVIENT?