https://www.avient.com/news/archives?page=43
PolyOne Showcases Expertise in Medical Polymers at Analytica China 2018 SHANGHAI – Oct 31, 2018 – PolyOne is highlighting its its full portfolio of medical plastics, including an extensive range of medical colorants an
https://www.avient.com/news/avient-announces-launch-biocompatible-peek-pre-colored-compounds-healthcare-medica-2024
Developed with the rigorous demands of the healthcare industry in mind, these innovative pre-colored compounds are formulated with materials that have been successfully tested for ISO 10993 biocompatibility, supporting compliance with the highest standards for medical applications. With ultra-high heat and chemical resistance, excellent mechanical properties, and dimensional stability, polyether ether ketone (PEEK) is an excellent material for applications in the medical field, particularly for applications requiring multiple sterilizations and rigorous disinfection methods. Our new Transcend Biocompatible PEEK pre-colored compounds can provide healthcare manufacturers with the flexibility and reliability they need to produce high-quality medical devices," said Deborah Sondag, Global Marketing Manager for Colorant Chromatics at Avient Corporation.
https://www.avient.com/news/medtec-china-2024-avient-announces-healthcare-tpu-manufacturing-expansion
The show, one of China's top medical technology exhibitions, starts today. To support this, Avient’s medical-grade colorants and additives are manufactured at sites certified under GMP or ISO 13485-2016 standards. Additionally, Avient’s ISO 13485 manufacturing site in Singapore for its Mevopur™ formulations recently achieved ISO/IEC 17025 accreditation for Biological Evaluation of Medical Devices–Part 5: Tests for In-Vitro Cytotoxicity.
https://www.avient.com/news/mecall-srl-replaces-lead-trilliant-radiation-shielding-polyone
– PolyOne Corporation (NYSE: POL), a premier global provider of specialized polymer materials, services and solutions, announced that medical device manufacturer Mecall S.r.l. has replaced lead in radiology equipment with Trilliant™ Radiation Shielding solutions from PolyOne. PolyOne Trilliant injection moldable solutions block radiation as effectively as lead, providing medical device manufacturers with an easy-to-manufacture and more sustainable alternative,” said Holger Kronimus, vice president, Europe and general manager, Engineered Materials Europe, PolyOne Corporation. PolyOne is exhibiting a full range of polymer, colorant and additive healthcare solutions this week at Medical Design & Manufacturing West in booth 3213.
https://www.avient.com/products/vivo-formulations-healthcare/neu-custom-capabilities
NEU™ Custom Capabilities offer a balance of material science expertise and technical application development to manufacture a short-term in-vivo catheter material that meets the formulation specifications for your medical application when performance and speed to market are paramount. Explore polymer, colorant and additive solutions for catheters & medical tubing Antimicrobial corrosion and chemical resistant formulations to solve your medical application challenges
https://www.avient.com/products/vinyl-formulations/vinyl-plastisols-organosols/core-vinyl-plastisols-healthcare
With a long and proven history of safe and effective use in medical applications, vinyl plastisols are some of the most often selected and versatile polymers in the healthcare market. The gold standard for enhancing polymer performance in medical applications. Standard and custom color solutions for today’s complex medical applications
https://www.avient.com/news/disinfectant-resistance-improved-trilliant-hc-polyone
Medical facilities are resorting to aggressive disinfecting regimens in efforts to prevent them, and hospital equipment is now being subjected to disinfection more frequently and with harsher cleaners. We enable our customers to reach their goals – improving patient outcomes with life-saving medical devices that incorporate more durable materials.”PolyOne is exhibiting Trilliant HC and other medical-grade materials in booth #2114 at MD&M Minneapolis.
https://www.avient.com/knowledge-base/case-study/andwin-scientific-innovation-improves-dosing-accuracy
Product engineers at Andwin Scientific, a leading manufacturer of medical and laboratory supplies, were determined to find a replacement for these wildly imprecise measuring methods. Andwin Scientific’s patented solution improves dosing accuracy, allows the end-user to use every drop of medication and reduces the chance for an accidental spill. With the dosing adapter in place, medication bottles also have an additional layer of child-resistance.
https://www.avient.com/sites/default/files/2020-09/stat-tech-tri-fold-processing-guide.pdf
Base Resin PC PC/PSU PES PEI PP ABS PEEK PA Barrel Temperatures* °F (°C) Rear Zone 530–560 (277–293) 550–575 (288–302) 660–700 (349–371) 675–725 (357–385) 390–420 (199–216) 425–460 (219–238) 680–730 (360–388) 430–500 (221–260) Center Zone 515–560 (269–288) 540–565 (282–296) 650–690 655–710 (352–377) 380–405 (193–207) 415–450 (213–232) 670–710 (354–377) 420–490 (216–254) Front Zone 510–525 (266–274) 530–555 (277–291) 640–680 (338–360) 655–700 (346–371) 370–395 (188–202) 405–440 (207–227) 410–480 (210–249) Nozzle 520–535 (271–280) 540–565 (282–296) 650–690 665–710 (352–377) 380–400 (193–204) 415–450 (213–232) 660–700 (349–371) 420–490 (216–254) Melt Temperature 525–560 (274–293) 530–580 (277–304) 650–700 (343–371) 660–730 (349–388) 375–395 (191–202) 410–460 (210–238) 650–730 (343–388) 420–500 (216–260) Mold Temperature 175–250 (80–121) 160–220 (71–104) 280–350 (138–177) 275–350 (135–177) 100–135 (38–57) 150–180 (66–82) 300–425 (149–219) 160–230 (71–110) Pack & Hold Pressure 50%–75% of Injection Pressure Injection Velocity in/s 0.5–2.0 Back Pressure psi 50 Screw Speed rpm 40–70 40–70 40–70 40–70 40–70 40–70 40–70 40–70** Drying Parameters °F (°C) 6 hrs @ 250 4 hrs @ 250 4 hrs @ 275 (135) 4 hrs @ 250 3 hrs @ 300 (150) 2 hrs @ 200 (93) 3 hrs @ 275 (135) 4 hrs @ 180 (82) Cushion in 0.125–0.250 Screw Compression Ratio 2.0:1–2.5:1 2.0:1–2.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1 Nozzle Type General General General General General General General Reverse Taper Clamp Pressure 5–6 Tons/in2 * A reverse temperature profile is important to obtain optimum conductive properties.
https://www.avient.com/sites/default/files/2022-10/2022 Automotive Industry Overview Brochure.pdf
Our global team is here to accelerate development and part approvals, supporting you with: • Materials that meet over 500 automotive polymer OEM specifications • More than 14,000 color and additive approvals for OEM specifications, including more than 2,000 UL94-registered concentrates and pre-colors • Advanced design and color expertise PORTFOLIO HIGHLIGHTS Specialized polymers and composites • Thermoplastic Elastomers • Recycled and Bio-based Thermoplastic Elastomers • Long Fiber Reinforced Formulations • Thermally Conductive Formulations • Static Dissipative, Electrically Conductive, and EMI/RFI Shielding Formulations • Pre-Colored Thermoplastics for Premium Finishes • Engineered Polymer Formulations • Continuous Fiber Tapes & Laminates Colorants, additives, and plastisols • Solid & Liquid Colorants (special effects & bio-based) • Colorant and Additive Concentrates • Functional and Performance Additives (UV, FR, antimicrobial, and more) • Liquid Additives • Chemical Foaming and Nucleating Agents • High-Temperature Concentrates • Silicone Dispersions • Vinyl Powders and Plastisols Design & Color Services • Avient Design • ColorWorks™ Design & Technology Centers UNDERHOOD Air Management Fuel Systems Filters/Cleaners Engines/Power train Fans & Shrouds Engine & Cam Covers Fluid Reservoirs Wire & Cable and Connectors Battery Systems & Supports EV Battery Systems Sensors/Controls/Actuators Turbo/Super Chargers Control Modules/Valves Gears & Hoses HVAC Systems Electrical Control Units EXTERIOR Move over metal... our material and colorant solutions enable you to replace metal and paint while improving miles per gallon or per charge.